Endress+Hauser HART Device DTM Vulnerability
OVERVIEW
Alexander Bolshev and Svetlana Cherkasova of Digital Security have identified an improper input vulnerability in the CodeWrights GmbH HART Device Type Manager (DTM) library used in Endress+Hauser HART Device DTM. CodeWrights GmbH has addressed the vulnerability with a new library, which Endress+Hauser has begun to integrate.
AFFECTED PRODUCTS
The following products use the vulnerable HART DTM library and are affected:
- Cerabar M / PMx 4x / V1.0 ... 1.2
- Cerabar M 5x / PMx 5x / V1.00.xx
- Cerabar S / PMx 7x / HART / FW 2.20.zz / Dev.Rev. 22
- Cerabar S / PMx 7x / V01.00
- Cerabar S / PMx 7x / V02.00
- Cerabar S / PMx 7x / V02.10.xx
- Cerabar S / PMx x3x / V1.x
- Cerabar S / PMx x3x / V2.x
- Cerabar S / PMx x3x / V3.x
- Cerabar S / PMx x3x / V5.0
- Cerabar S / PMx x3x / V7.1
- Deltabar / FMD 7x / HART / FW 1.00.zz / Dev.Rev. 1
- Deltabar M 5x / PMD 55 / V1.00.xx
- Deltabar S / xMD 7x / HART / FW 2.20.zz / Dev.Rev. 22
- Deltabar S / xMD 7x / V01.00
- Deltabar S / xMD 7x / V02.00
- Deltabar S / xMD 7x / V02.10.xx
- Deltabar S / xMD x3x / V1.x
- Deltabar S / xMD x3x / V2.x
- Deltabar S / xMD x3x / V5.0
- Deltabar S / xMD x3x / V7.1
- Deltapilot M 5x / FMB 5x / V1.00.xx
- Deltapilot S / DB 5x / V1.x
- Deltapilot S / DB 5x / V2.0
- Deltapilot S / FMB 70 / HART / FW 2.20.zz / Dev.Rev. 22
- Deltapilot S / FMB 70 / V02.10.xx
- Gammapilot M / FMG 60 / HART / FW 1.04.zz / Dev.Rev. 3
- Gammapilot M / FMG 60 / V01.xx
- Gammapilot M / FMG 60 / V02.xx
- iTemp / TMT 122 / V1.1
- iTemp / TMT 142 / V1.03.00
- iTemp / TMT 162 / V1.00.00 ... 1.02.00
- iTemp / TMT 162 / V1.03.00
- iTemp / TMT 182 / V1.1
- iTEMP / TMT82 / HART / FW 1.00.zz / Dev.Rev. 1
- Levelflex / FMP 2xx / V2.0 ... 2.1
- Levelflex M / FMP 40 / V2.00
- Levelflex M / FMP 4x / V4.xx
- Levelflex M Int / FMP 4x I / V1.08
- Liquicap M / FMI 5x / 1.00.xx
- Liquicap M / FMI 5x / 1.03.xx
- Liquiline Cond / CM 42 / HART / FW 2.01.zz / Dev.Rev. 1
- Liquiline M / CM44x / FW 1.02.zz / Dev.Rev. 1
- Liquiline M Cci / CM 42 / HART / FW 13.06.zz / Dev.Rev. 10
- Liquiline M Cci / CM 42 / HART / FW 13.07.zz / Dev.Rev. 11
- Liquiline M Cci / CM 42 / V13.01.xx
- Liquiline M Cci / CM 42 / V13.04.07
- Liquiline M Cci / CM 42 / V13.05.xx
- Liquiline M DO / CM 42 / HART / FW 20.04.zz / Dev.Rev. 17
- Liquiline M DO / CM 42 / HART / FW 20.05.zz / Dev.Rev. 18
- Liquiline M DO / CM 42 / V20.02.07
- Liquiline M DO / CM 42 / V20.02.xx
- Liquiline M DO / CM 42 / V20.03.xx
- Liquiline M pH-ORP / CM 42 / HART / FW 10.06.zz / Dev.Rev. 0D
- Liquiline M pH-ORP / CM 42 / HART / FW 10.07.zz / Dev.Rev. 0E
- Liquiline M pH-ORP / CM 42 / V10.02.xx
- Liquiline M pH-ORP / CM 42 / V10.04.07
- Liquiline M pH-ORP / CM 42 / V10.04.xx
- Liquiline M pH-ORP / CM 42 / V10.05.xx
- Liquiline Oxygen / CM 42 / HART / FW 2.01.zz / Dev.Rev. 1
- Liquiline pHORP / CM 42 / HART / FW 2.01.zz / Dev.Rev. 1
- Liquiport / CSPxx / HART / FW 01.02.zz / Dev.Rev.1
- Liquistation / CSFxx / HART / FW 01.02.zz / Dev.Rev.1
- Liquisys M Chlorine / CCM 2x3 / V2.30
- Liquisys M Chlorine / CCM 2x3 / V2.35
- Liquisys M Cond. C / CLM 2x3 / V2.30
- Liquisys M Cond. I / CLM 2x3 / V2.30
- Liquisys M DO / COM 2x3 / V2.40
- Liquisys M PH / CPM 2x3 / V2.50
- Liquisys M Turbidity / CUM 2x3 / V2.40
- Micropilot I / FMR 13x / V1.4
- Micropilot I / FMR 13x / V1.5
- Micropilot I / FMR 13x / V2.0
- Micropilot I / FMR 13x / V2.1
- Micropilot II / FMR 23x / V2.0
- Micropilot M / FMR 25x / V1.00
- Micropilot M / FMR 25x / V4.xx
- Micropilot M / FMR 25x / V5.xx
- Micropilot M / FMR 2xx / V1.02
- Micropilot M / FMR 2xx / V2.00
- Micropilot M / FMR 2xx / V4.xx
- Micropilot S / FMR 53x / V1.02
- Micropilot S / FMR 53x / V2.00
- Micropilot S / FMR 53x / V3.00
- Micropilot S / FMR 540 / V01.01.xx
- Multicap / FEC 12 / V1.0 ... 1.2
- Mycom S Cond. C / CLM 153 / V1.20
- Mycom S Cond. I / CLM 153 / V1.20
- Mycom S PH / CPM 153 / V2.30
- Mypro Cond. C / CLx 431 / V2.05
- Mypro Cond. I / CLx 431 / V2.10
- Mypro PH / CPM 431 / V2.02
- Nivotester / FTC625 / V1.2
- Omnigrad / TMD 832 / V1.1 ... 1.3
- Omnigrad / TMD 833 / V1.0 ... 1.1
- Omnigrad / TMD 842 / V1.1 ... 1.3
- Promag / 10 / V1.00.00 ... V1.00.02
- Promag / 10 / V1.01.00
- Promag / 10 / V1.02.00
- Promag / 10 / V1.03.00
- Promag / 23 / V2.00.00 ... 2.01.00
- Promag / 23 / V2.02.00 ... 2.03.00
- Promag / 33 / V2.04.00
- Promag / 35 S / V2.04.00
- Promag / 39 / V2.04.00
- Promag / 50 / HART / FW 2.04.zz / Dev.Rev. 9
- Promag / 50 / V1.02.0x
- Promag / 50 / V1.04.0x
- Promag / 50 / V1.06.0x
- Promag / 50 / V2.00.00
- Promag / 50 / V2.01.xx
- Promag / 50 / V2.02.xx
- Promag / 50 / V2.03.xx
- Promag / 51 / HART / FW 2.04.zz / Dev.Rev. 9
- Promag / 51 / V1.04.0x
- Promag / 51 / V1.06.0x
- Promag / 51 / V2.00.0x
- Promag / 51 / V2.01.xx
- Promag / 51 / V2.02.xx
- Promag / 51 / V2.03.xx
- Promag / 53 / HART / FW 2.03.zz / Dev.Rev. 8
- Promag / 53 / HART / FW 2.07.zz / Dev.Rev. 9 .
- Promag / 53 / V1.02.0x
- Promag / 53 / V1.04.0x
- Promag / 53 / V1.06.00
- Promag / 53 / V2.00.00
- Promag / 53 / V2.01.xx
- Promag / 53 / V2.02.xx
- Promag / 55 / HART / FW 1.03.zz / Dev.Rev. 4
- Promag / 55 / V1.00.xx
- Promag / 55 / V1.01.xx
- Promag / 55 / V1.02.xx
- Promass / 40 / V1.02.0x
- Promass / 40 / V1.04.0x
- Promass / 40 / V1.05.0x
- Promass / 40 / V1.06.0x
- Promass / 40 / V2.00.0x
- Promass / 40 / V2.01.0x
- Promass / 40 / V2.02.0x
- Promass / 40 / V3.01.0x
- Promass / 60 / V3.01.xx
- Promass / 60 / V3.02.xx
- Promass / 60 / V3.03.01
- Promass / 63 / V2.02.xx
- Promass / 63 / V3.00.00
- Promass / 63 / V3.02.00
- Promass / 63 / V3.03.01
- Promass / 80 / V1.02.0x
- Promass / 80 / V1.04.0x
- Promass / 80 / V1.05.0x
- Promass / 80 / V1.06.0x
- Promass / 80 / V2.00.0x
- Promass / 80 / V2.01.0x
- Promass / 80 / V2.02.0x
- Promass / 80 / V3.01.0x
- Promass / 83 / HART / FW 3.07.zz / Dev.Rev. 0A
- Promass / 83 / V1.02.0x
- Promass / 83 / V1.04.0x
- Promass / 83 / V1.05.0x
- Promass / 83 / V1.06.0x
- Promass / 83 / V2.00.0x
- Promass / 83 / V2.01.0x
- Promass / 83 / V2.02.0x
- Promass / 83 / V3.01.0x
- Promass / 84 / V2.00.0x
- Promass / 84 / V2.01.0x
- Promass / 84 / V2.02.0x
- Promass / 84 / V3.01.0x
- Proservo / NMS 530 / V1.0
- Prosonic / FMU 860 / V2.1
- Prosonic / FMU 860 / V2.2 ... 2.3
- Prosonic / FMU 861 / V2.1
- Prosonic / FMU 861 / V2.2 ... 2.3
- Prosonic / FMU 862 / V2.1
- Prosonic / FMU 862 / V2.2 ... 2.3
- Prosonic Flow / 90 / V1.04.0x
- Prosonic Flow / 90 / V1.06.0x
- Prosonic Flow / 90 / V2.00.0x
- Prosonic Flow / 90 / V2.01.0x
- Prosonic Flow / 91 / HART / FW 1.02.zz / Dev.Rev. 3
- Prosonic Flow / 91 / V1.00.xx
- Prosonic Flow / 91 / V1.01.xx
- Prosonic Flow / 92 / HART / FW 1.01.zz / Dev.Rev. 2
- Prosonic Flow / 92 / V1.00.xx
- Prosonic Flow / 93 / HART / FW 2.03.zz / Dev.Rev. 8
- Prosonic Flow / 93 / V1.04.0x
- Prosonic Flow / 93 / V1.05.0x
- Prosonic Flow / 93 / V1.06.0x
- Prosonic Flow / 93 / V2.00.0x
- Prosonic Flow / 93 / V2.01.0x
- Prosonic Flow / 93 / V2.02.0x
- Prosonic Flow / DMU93 / V1.00.00
- Prosonic Flow / DMU93 / V1.01.00
- Prosonic M / FMU 4x / V2.00
- Prosonic M / FMU 4x / V4.xx
- Prosonic S / FMU 90 / V2.00.xx
- Prosonic S / FMU 90 / V2.01.xx
- Prosonic S / FMU 9x / V01.00.xx
- Prosonic T / FMU x3x / V2.1 ... 2.2
- Prothermo / NMT 539(1) / V1.0
- Prothermo / NMT 539(2) / V1.0
- Prothermo / NMT539(1) / HART / FW 1.5z / Dev.Rev. 5
- Prothermo / NMT539(2) / HART / FW 1.5z / Dev.Rev. 5
- Prowirl / 70 / ... V1.1.01
- Prowirl / 72 / HART / FW 1.06.zz / Dev.Rev. 7
- Prowirl / 72 / V1.00.00 ... V1.01.01
- Prowirl / 72 / V1.02.00
- Prowirl / 72 / V1.03.00
- Prowirl / 72 / V1.04.00
- Prowirl / 72 / V1.05.00
- Prowirl / 73 / HART / FW 1.06.zz / Dev.Rev. 7
- Prowirl / 73 / V1.00.0x
- Prowirl / 73 / V1.01.0x
- Prowirl / 73 / V1.02.0x
- Prowirl / 73 / V1.03.0x
- Prowirl / 73 / V1.04.0x
- Prowirl / 73 / V1.05.0x
- Prowirl / 77 / ... V1.0.06
- Smartec S / CLD 132 / V1.11
- Tank Side Monitor / NRF 590 / V2.04.xx
- t-mass / 65 / V1.00.xx
- t-mass / 65 / V1.01.xx
- t-mass / 70 / V2.0
- Waterpilot 2x / FMX 21 / V1.00.xx.
IMPACT
The vulnerability could cause a buffer overflow in the HART Device DTM, crashing the Field Device Tool (FDT) Frame Application. The Frame Application must then be restarted to restore functionality. The Frame Application is used primarily for remote configuration. Exploitation of this vulnerability does not result in loss of information, control, or view by the control system of the HART devices on the 4-20 mA HART Loop.
Impact to individual organizations depends on many factors that are unique to each organization and systems implementation. NCCIC/ICS-CERT recommends that organizations evaluate the impact of this vulnerability based on their operational environment, architecture, and product implementation.
BACKGROUND
Endress+Hauser is an International-based company based in Germany and Switzerland, with over 200 offices and production centers located worldwide.
The affected product is the DTM library used by Endress+Hauser HART-based field devices in the FDT/DTM Frame Application. According to Endress+Hauser, these products are deployed across multiple critical infrastructure sectors worldwide.
VULNERABILITY CHARACTERISTICS
VULNERABILITY OVERVIEW
IMPROPER INPUT VALIDATIONCWE-20: Improper Input Validation, http://cwe.mitre.org/data/definitions/20.html, web site last accessed August 25, 2015.
Successful injection of specially crafted packets to the Device DTM causes a buffer overflow condition in the Frame Application. The FDT Frame Application becomes unresponsive, and the Device DTM stops functioning.
CVE-2014-9191NVD, http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2014-9191, web site last accessed August 25, 2015. has been assigned to this vulnerability. A CVSS v2 base score of 1.8 has been assigned; the CVSS vector string is (AV:A/AC:H/Au:N/C:N/I:N/A:P).CVSS Calculator, http://nvd.nist.gov/cvss.cfm?version=2&vector=AV:A/AC:H/Au:N/C:N/I:N/A:P, web site last accessed August 25, 2015.
VULNERABILITY DETAILS
EXPLOITABILITY
This exploit on the FDT/DTM Frame Application is possible from any adjacent network that receives or passes packets from the HART Device DTM.
EXISTENCE OF EXPLOIT
No known public exploits specifically target this vulnerability.
DIFFICULTY
This is a complex vulnerability. Crafting a working exploit for this vulnerability would be difficult. Compromised access that allows access to the packets transmitted to Frame Application is required for exploitation. This exploit also requires a specific timing to crash the Frame Application. This increases the difficulty of a successful exploit.
MITIGATION
Endress+Hauser has released a security update addressing the HART Device DTMs. The update can be downloaded here:
https://portal.endress.com/webdownload/FieldCareDownloadGui/http://www.us.endress.com/en/online-tools-assist-around-the-clock/process-instrument-support
Endress+Hauser Inc. - Technical supportTel.: 888-ENDRESStechsupport@us.endress.comwww.us.endress.com/support-options
Endress+Hauser has recommended owners/operators to update HART DTM library 2.41 and FDT tool FieldCare to Version 2.10. For further information please consult the Release Notes and the Technical Information.
ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:
- Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.
- Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
- When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page at: http://ics-cert.us-cert.gov/content/recommended-practices. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Additional mitigation guidance and recommended practices are publicly available in the ICS‑CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site (http://ics-cert.us-cert.gov/).
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.
Vendor
Endress+Hauser