VideoInsight Web Client
CVSS V3 7.3
AFFECTED PRODUCTS
The following Web Client versions are affected:
- Web Client Version 6.3.5.11 and previous versions.
IMPACT
A successful exploit of this vulnerability could allow an attacker to execute arbitrary commands on the target system.
MITIGATION
VideoInsight has produced a new version that addresses the reported vulnerability.
The latest Version 6.3.6.11 is available on the download portal at the following link: www.downloadvi.com
NCCIC/ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:
- Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.
- Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
- When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available in the ICS‑CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.
No known public exploits specifically target this vulnerability.
VULNERABILITY OVERVIEW
A SQL Injection vulnerability has been identified, which may allow remote code execution.
CVE-2017-5151 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L).
RESEARCHER
Juan Pablo Lopez Yacubian reported this vulnerability and has tested the patch.
Vendor
VideoInsight