Archived Content
In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.PHOENIX CONTACT FL SWITCH
CVSS v3 9.8
ATTENTION: Remotely exploitable/low skill level to exploit.
Vendor: PHOENIX CONTACT
Equipment: FL SWITCH
Vulnerabilities: Improper Authorization, Information Exposure
AFFECTED PRODUCTS
All FL SWITCH 3xxx, 4xxx, and 48xxx Series products running firmware Version 1.0 to 1.32 are affected.
IMPACT
Successful exploitation of these vulnerabilities may allow an unauthenticated remote attacker to gain administrative privileges and expose information to unauthenticated users.
MITIGATION
PHOENIX CONTACT recommends that affected users upgrade to firmware Version 1.33 or higher. The updated firmware may be downloaded from the following locations:
- FL SWITCH 3005:
http://www.phoenixcontact.net/qr/2891030/firmware_update
- FL SWITCH 3005T:
http://www.phoenixcontact.net/qr/2891032/firmware_update
- FL SWITCH 3004T-FX
http://www.phoenixcontact.net/qr/2891033/firmware_update
- FL SWITCH 3004T-FX ST
http://www.phoenixcontact.net/qr/2891034/firmware_update
- FL SWITCH 3008
http://www.phoenixcontact.net/qr/2891031/firmware_update
- FL SWITCH 3008T
http://www.phoenixcontact.net/qr/2891035/firmware_update
- FL SWITCH 3006T-2FX
http://www.phoenixcontact.net/qr/2891036/firmware_update
- FL SWITCH 3006T-2FX ST
http://www.phoenixcontact.net/qr/2891037/firmware_update
- FL SWITCH 3012E-2SFX
http://www.phoenixcontact.net/qr/2891067/firmware_update
- FL SWITCH 3016E
http://www.phoenixcontact.net/qr/2891066/firmware_update
- FL SWITCH 3016
http://www.phoenixcontact.net/qr/2891058/firmware_update
- FL SWITCH 3016T
http://www.phoenixcontact.net/qr/2891059/firmware_update
- FL SWITCH 3006T-2FX SM
http://www.phoenixcontact.net/qr/2891060/firmware_update
- FL SWITCH 4008T-2SFP
http://www.phoenixcontact.net/qr/2891062/firmware_update
- FL SWITCH 4008T-2GT-4FX SM
http://www.phoenixcontact.net/qr/2891061/firmware_update
- FL SWITCH 4008T-2GT-3FX SM
http://www.phoenixcontact.net/qr/2891160/firmware_update
- FL SWITCH 4808E-16FX LC-4GC
http://www.phoenixcontact.net/qr/2891073/firmware_update
- FL SWITCH 4808E-16FX SM-4GC
http://www.phoenixcontact.net/qr/2891080/firmware_update
- FL SWITCH 4808E-16FX SM ST-4GC
http://www.phoenixcontact.net/qr/2891086/firmware_update
- FL SWITCH 4808E-16FX ST-4GC
http://www.phoenixcontact.net/qr/2891085/firmware_update
- FL SWITCH 4808E-16FX-4GC
http://www.phoenixcontact.net/qr/2891079/firmware_update
- FL SWITCH 4808E-16FX SM LC-4GC
http://www.phoenixcontact.net/qr/2891074/firmware_update
- FL SWITCH 4012T 2GT 2FX
http://www.phoenixcontact.net/qr/2891063/firmware_update
- FL SWITCH 4012T-2GT-2FX ST
http://www.phoenixcontact.net/qr/2891161/firmware_update
- FL SWITCH 4824E-4GC
http://www.phoenixcontact.net/qr/2891072/firmware_update
- FL SWITCH 4800E-24FX-4GC
http://www.phoenixcontact.net/qr/2891102/firmware_update
- FL SWITCH 4800E-24FX SM-4GC
http://www.phoenixcontact.net/qr/2891104/firmware_update
- FL SWITCH 4800E-24FX SM-4GC
http://www.phoenixcontact.net/qr/2891120/firmware_update
- FL SWITCH 3012E-2FX SM
http://www.phoenixcontact.net/qr/2891119/firmware_update
- FL SWITCH 4000T-8POE-2SFP-R
http://www.phoenixcontact.net/qr/2891162/firmware_update
NCCIC/ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:
- Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.
- Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
- When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available in the ICS‑CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.
No known public exploits specifically target these vulnerabilities.
VULNERABILITY OVERVIEW
A remote unauthenticated attacker may be able to craft special HTTP requests allowing an attacker to bypass web-service authentication allowing the attacker to obtain administrative privileges on the device.
CVE-2017-16743 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
A remote unauthenticated attacker may be able to use Monitor Mode on the device to read diagnostic information.
CVE-2017-16741 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).
RESEARCHER
Ilya Karpov and Evgeniy Druzhinin of Positive Technologies discovered these vulnerabilities. PHOENIX CONTACT reported to CERT@VDE that their products are affected. CERT@VDE coordinated these vulnerabilities with ICS-CERT.
BACKGROUND
Critical Infrastructure Sectors: Communications, Critical Manufacturing, Information Technology
Countries/Areas Deployed: Worldwide
Company Headquarters Location: Germany
This product is provided subject to this Notification and this Privacy & Use policy.
Vendor
- PHOENIX CONTACT