In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L and FX Series CPU Modules (Update A)
1. EXECUTIVE SUMMARY
- CVSS v3 10.0
- ATTENTION: Exploitable remotely/low skill level to exploit
- Vendor: Mitsubishi Electric
- Equipment: MELSEC
- Vulnerability: Cleartext Transmission of Sensitive Information
2. UPDATE INFORMATION
This updated advisory is a follow-up to the original advisory titled ICSA-20-175-01 Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L and FX Series CPU Modules that was published June 23, 2020, on the ICS webpage on us-cert.gov.
3. RISK EVALUATION
Successful exploitation of this vulnerability could allow information disclosure, information tampering, unauthorized operation, or a denial-of-service condition.
4. TECHNICAL DETAILS
4.1 AFFECTED PRODUCTS
Mitsubishi Electric reports the vulnerability affects the following MELSEC products:
- MELSEC iQ-R, iQ-F, Q, L and FX series CPU modules, all versions
4.2 VULNERABILITY OVERVIEW
4.2.1 CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319
There is a vulnerability due to cleartext communication between Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules, and GX Works3/GX Works2. There are risks of communication data eavesdropping/tampering, unauthorized operation, and denial-of-service (DoS) attacks from attackers.
--------- Begin Update A Part 1 of 2 ---------
CVE-2020-5594 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).
--------- End Update A Part 1 of 2 ---------
4.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
- COUNTRIES/AREAS DEPLOYED: Worldwide
- COMPANY HEADQUARTERS LOCATION: Japan
4.4 RESEARCHER
Shunkai Zhu, Rongkuan Ma and Peng Cheng from NESC Lab of Zhejiang University reported this vulnerability to Mitsubishi Electric.
5. MITIGATIONS
Mitsubishi Electric recommends encrypting the communication path by setting up a VPN to mitigate the impact of this vulnerability.
--------- Begin Update A Part 2 of 2 ---------
Additional information about the vulnerability is available by contacting a Mitsubishi Electric representative.
https://us.mitsubishielectric.com/fa/en/about-us/distributors
--------- End Update A Part 2 of 2 ---------
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:
- Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.
- Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
- When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
No known public exploits specifically target this vulnerability.