In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.Siemens SIMATIC HMI Products (Update A)
1. EXECUTIVE SUMMARY
- CVSS v3 6.5
- ATTENTION: Exploitable remotely/low attack complexity
- Vendor: Siemens
- Equipment: SIMATIC HMI
- Vulnerabilities: Improper Restriction of Excessive Authentication Attempts, Authentication Bypass by Primary Weakness
2. UPDATE INFORMATION
This updated advisory is a follow-up to the original advisory titled ICSA-20-252-06 Siemens SIMATIC HMI Products that was published September 8, 2020, to the ICS webpage on us-cert.cisa.gov.
3. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.
4. TECHNICAL DETAILS
4.1 AFFECTED PRODUCTS
--------- Begin Update A Part 1 of 2 ---------
The following versions of Siemens SIMATIC HMI Products are affected:
- SIMATIC HMI Basic Panels, 2nd Generation (incl. SIPLUS variants): All versions prior to v16 are affected by CVE-2020-15786
- SIMATIC HMI Comfort Panels (incl. SIPLUS variants): All versions up to and including v16 are affected by CVE-2020-15786
- SIMATIC HMI Mobile Panels: All versions up to and including v16 are affected by CVE-2020-15786
- SIMATIC HMI United Comfort Panels: All versions up to and including v16
--------- End Update A Part 1 of 2 ---------
4.2 VULNERABILITY OVERVIEW
4.2.1 IMPROPER RESTRICTION OF EXCESSIVE AUTHENTICATION ATTEMPTS CWE-307
Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.
CVE-2020-15786 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L).
4.2.2 AUTHENTICATION BYPASS BY PRIMARY WEAKNESS CWE-305
Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.
CVE-2020-15787 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N).
4.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Energy
- COUNTRIES/AREAS DEPLOYED: Worldwide
- COMPANY HEADQUARTERS LOCATION: Germany
4.4 RESEARCHER
Joseph Gardiner from Bristol Cyber Security Group, University of Bristol, reported these vulnerabilities to Siemens.
5. MITIGATIONS
--------- Begin Update A Part 2 of 2 ---------
Siemens has released updates for the affected products and recommends users update to the latest versions.
- SIMATIC HMI Basic Panels 2nd Generation: Update to v16 Update 3
- SIMATIC HMI Comfort Panels: Update to v16 Update 3
- SIMATIC HMI Mobile Panels: Update to v16 Update 3
- SIMATIC HMI Unified Comfort Panels: Update to v16 Update 3
Siemens has identified the following specific workarounds and mitigations users can apply to reduce the risk:
- Apply defense-in-depth strategies.
- For Unified Comfort Panels using SmartClient: The password truncation (CVE-2020-15787) cannot be resolved due to RFC 6143 and is limited to 8 characters. Complex passwords are recommended.
--------- End Update A Part 2 of 2 ---------
As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens operational guidelines for Industrial Security and following the recommendations in the product manuals.
For additional information, please refer to Siemens Security Advisory SSA-542525
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
No known public exploits specifically target these vulnerabilities.