ICS Advisory

Siemens JT2Go and Teamcenter Visualization

Last Revised
Alert Code
ICSA-21-194-15

1. EXECUTIVE SUMMARY

  • CVSS v3 7.8
  • ATTENTION: Low attack complexity
  • Vendor: Siemens
  • Equipment: JT2Go and Teamcenter Visualization
  • Vulnerabilities: Double Free, Infinite Loop, Out-of-bounds Write, Use After Free, Heap-based Buffer Overflow, Buffer Over-read, Out-of-bounds Read, Improper Restriction of Operations within the Bounds of a Memory Buffer

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could lead to application crash or potentially arbitrary code execution on the target host system.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following Siemens products are affected:

  • JT2Go: All versions prior to v13.2
  • Teamcenter Visualization: All versions prior to v13.2

3.2 VULNERABILITY OVERVIEW

3.2.1    DOUBLE FREE CWE-415

The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. A malformed input file could result in a double free of an allocated buffer that leads to a crash. An attacker could leverage this vulnerability to cause denial-of-service condition.

CVE-2021-34333 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H).

3.2.2    LOOP WITH UNREACHABLE EXIT CONDITION ('INFINITE LOOP') CWE-835

The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. A malformed input file could result in an infinite loop condition that leads to a denial-of-service condition. An attacker could leverage this vulnerability to consume excessive resources.

CVE-2021-34332 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H).

3.2.3    OUT-OF-BOUNDS WRITE CWE-787

The Jt981.dll library in affected applications lacks proper validation of user-supplied data when parsing JT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34331 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.4    USE AFTER FREE CWE-416

The Jt981.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing JT files. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34330 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.5    HEAP-BASED BUFFER OVERFLOW CWE-122

The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code. The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34329 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.6    HEAP-BASED BUFFER OVERFLOW CWE-122

The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34328 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.7    HEAP-BASED BUFFER OVERFLOW CWE-122

The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing ASM files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34327 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.8    HEAP-BASED BUFFER OVERFLOW CWE-122

The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34326 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.9    BUFFER OVER-READ CWE-126

The Jt981.dll library in affected applications lacks proper validation of user-supplied data when parsing JT files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.

CVE-2021-34325 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).

3.2.10    USE AFTER FREE CWE-416

The Jt981.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing JT files. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34324 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is  (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.11    OUT-OF-BOUNDS WRITE CWE-787

The Jt981.dll library in affected applications lacks proper validation of user-supplied data when parsing JT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34323 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.12    BUFFER OVER-READ CWE-126

The JPEG2K_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing J2K files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.

CVE-2021-34322 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).

3.2.13    BUFFER OVER-READ CWE-126

The VisDraw.dll library in affected applications lacks proper validation of user-supplied data when parsing J2K files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.

CVE-2021-34321 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).

3.2.14    BUFFER OVER-READ CWE-126

The Jt981.dll library in affected applications lacks proper validation of user-supplied data when parsing JT files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.

CVE-2021-34320 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).

3.2.15    OUT-OF-BOUNDS WRITE CWE-787

The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing SGI files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34319 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.16    OUT-OF-BOUNDS WRITE CWE-787

The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing PCT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34318 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.17    HEAP-BASED BUFFER OVERFLOW CWE-122

The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing PCX files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34317 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.18    OUT-OF-BOUNDS WRITE CWE-787

The DL180CoolType.dll library in affected applications lacks proper validation of user-supplied data when parsing PDF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34316 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.19    OUT-OF-BOUNDS READ CWE-125

The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing SGI files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34315 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.20    OUT-OF-BOUNDS WRITE CWE-787

The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing SGI files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34314 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is  (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.21    HEAP-BASED BUFFER OVERFLOW CWE-122

The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34313 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.22    HEAP-BASED BUFFER OVERFLOW CWE-122

The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34312 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.23    OUT-OF-BOUNDS WRITE CWE-787

The Mono_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing J2K files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34311 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.24    OUT-OF-BOUNDS WRITE CWE-787

The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34310 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.25    OUT-OF-BOUNDS WRITE CWE-787

The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34309 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.26    BUFFER OVER-READ CWE-126

The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.

CVE-2021-34308 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).

3.2.27    BUFFER OVER-READ CWE-126

The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.

CVE-2021-34307 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).

3.2.28    IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119

The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34306 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.29    OUT-OF-BOUNDS WRITE CWE-787

The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34305 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is  (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.30    BUFFER OVER-READ CWE-126

The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.

CVE-2021-34304 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).

3.2.31    BUFFER OVER-READ CWE-126

The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.

CVE-2021-34303 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).

3.2.32    BUFFER OVER-READ CWE-126

The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.

CVE-2021-34302 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).

3.2.33    USE AFTER FREE CWE-416

The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing BMP files. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34301 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.34    OUT-OF-BOUNDS WRITE CWE-787

The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds write past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34300 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.35    BUFFER OVER-READ CWE-126

The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.

CVE-2021-34299 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).

3.2.36    USE AFTER FREE CWE-416

The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing BMP files. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34298 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.37    OUT-OF-BOUNDS WRITE CWE-787

The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34297 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.38    OUT-OF-BOUNDS READ CWE-125

The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34296 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.39    OUT-OF-BOUNDS WRITE CWE-787

The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34295 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.40    OUT-OF-BOUNDS READ CWE-125

The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34294 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.41    OUT-OF-BOUNDS WRITE CWE-787

The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34293 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.42    OUT-OF-BOUNDS READ CWE-125

The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34292 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.43    OUT-OF-BOUNDS WRITE CWE-787

The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-34291 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Multiple
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Brian Gorenc and Mat Powell of Trend Micro Zero Day Initiative; garmin and xina1i at SecZone; and Tran Van Khang - khangkito (VinCSS) working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has provided remediations for the following affected products:

As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.

Additional information on industrial security by Siemens can be found at: https://www.siemens.com/industrialsecurity 

For more information about these vulnerabilities and the associated remediations, please see Siemens publication number SSA-483182

CISA recommends users take the following measures to protect themselves from social engineering attacks:

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.



CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.



Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.

No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.