In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.Johnson Controls Sensormatic Electronics Illustra
1. EXECUTIVE SUMMARY
- CVSS v3 7.8
- ATTENTION: Low attack complexity
- Vendor: Sensormatic Electronics, LLC, a subsidiary of Johnson Controls, Inc.
- Equipment: Illustra
- Vulnerability: Off-by-one Error
2. RISK EVALUATION
Successful exploitation of this vulnerability could allow a local attacker to obtain super user access to the underlying Linux operating system.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
Johnson Controls reports this vulnerability affects the following Sensormatic Electronics Illustra camera systems:
- Pro Gen 3, All versions prior to 2.8.0
- Flex Gen 2, All versions prior to 1.9.4
- Pro 2, All versions
- Insight, All versions prior to 1.4.0
3.2 VULNERABILITY OVERVIEW
3.2.1 OFF-BY-ONE ERROR CWE-193
Under specific circumstances, a local attacker could exploit this vulnerability to obtain super user access to the underlying Linux operating system.
CVE-2021-3156 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
3.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
- COUNTRIES/AREAS DEPLOYED: Worldwide
- COMPANY HEADQUARTERS LOCATION: Ireland
3.4 RESEARCHER
Johnson Controls reported this vulnerability to CISA.
4. MITIGATIONS
Users are recommended update to one of the following firmware versions:
- Pro Gen 3, upgrade to Version 2.8.0
- Flex Gen 2, upgrade to Version 1.9.4
- Pro 2 is EOL
- Insight, upgrade to Version 1.4.0
For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2021-13
Johnson Controls recommends taking steps to minimize risks to all building automation systems.
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:
- Ensure the least-privilege user principle is followed.
- Restrict physical access to the device to authorized personnel only.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.
This product is provided subject to this Notification and this Privacy & Use policy.