Siemens JTTK and JT Utilities
1. EXECUTIVE SUMMARY
- CVSS v3 7.8
- ATTENTION: Low attack complexity
- Vendor: Siemens
- Equipment: JTTK and JT Utilities
- Vulnerabilities: Out-of-bounds Write, Out-of-bounds Read
2. RISK EVALUATION
Successful exploitation of these vulnerabilities could cause the application to crash or allow arbitrary code execution.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following versions of JT Open Toolkit (JTTK), an application programming interface, and JT Utilities, a series of command line utilities, are affected:
- JT Utilities: All versions prior to v12.8.1.1
- JTTK: All versions prior to v10.8.1.1
3.2 VULNERABILITY OVERVIEW
3.2.1 OUT-OF-BOUNDS WRITE CWE-787
JTTK library in affected products contains an out-of-bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.
CVE-2021-44449 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
3.2.2 OUT-OF-BOUNDS READ CWE-125
JTTK library in affected products is vulnerable to an out-of-bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak information in the context of the current process.
CVE-2021-44450 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
3.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
- COUNTRIES/AREAS DEPLOYED: Worldwide
- COMPANY HEADQUARTERS LOCATION: Germany
3.4 RESEARCHER
Bentley Systems Incorporated coordinated these vulnerabilities with Siemens.
4. MITIGATIONS
Siemens recommends updating to the latest versions, specifically:
- JT Utilities: Update to v12.8.1.1 or later version
- JTTK: Update to v10.8.1.1 or later version
Siemens has identified the following specific workarounds and mitigations users can apply to reduce the risk:
- Do not open untrusted files from unknown sources using JTTK
- Do not open untrusted files from unknown sources using JT Utilities
As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security, and follow the recommendations in the product manuals.
For more information about this issue, please see Siemens security advisory SSA-396621
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact Siemens ProductCERT.
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.