Mitsubishi Electric Factory Automation Products
1. EXECUTIVE SUMMARY
- CVSS v3 8.8
- ATTENTION: Low attack complexity
- Vendor: Mitsubishi Electric
- Equipment: Factory Automation (FA) Products
- Vulnerabilities: Dependency on Vulnerable Third-Party Component
2. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow a malicious attacker to escalate privileges, disclose parameter information in the affected products, and cause a denial-of-service condition.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following Mitsubishi Electric Factory Automation products are affected:
- MELIPC Series
- MI5122-VM: All versions
- MI1002-W: All versions
- MI2012-W: All versions
- MI3321G-W: All versions
- MI3315G-W: All versions
- MELSEC iQ-R Series
- R102WCPU-W: All versions
- MELSEC Q Series
- Q24DHCCPU-V: All versions
- Q24DHCCPU-VG: All versions
- Q24DHCCPU-LS: All versions
- Q26DHCCPU-LS: All versions
For the correspondence table of the affected products and each vulnerability, refer to Mitsubishi Electric’s security bulletin.
3.2 VULNERABILITY OVERVIEW
3.2.1 DEPENDENCY ON VULNERABLE THIRD-PARTY COMPONENT CWE-1395
These vulnerabilities in Intel products could allow a malicious attacker to escalate privileges, disclose parameter information, and cause a denial-of-service condition in Mitsubishi Electric MELIPC, MELSEC iQ-R, and MELSEC Q Series products.
CVE-2020-24489, CVE-2020-8670, CVE-2020-24512, CVE-2021-0146, CVE-2021-0089, CVE-2021-0086, CVE-2021-0127, CVE-2021-33150, CVE-2022-0002 has been assigned to these vulnerabilities. A worst-case CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H).
3.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
- COUNTRIES/AREAS DEPLOYED: Worldwide
- COMPANY HEADQUARTERS LOCATION: Japan
3.4 RESEARCHER
Mitsubishi Electric reported these vulnerabilities to CISA.
4. MITIGATIONS
Mitsubishi Electric recommends users refer to the following Intel advisories to assist in mitigating these vulnerabilities:
- CVE-2020-8670—INTEL-SA-00463
- CVE-2020-24489—INTEL-SA-00442
- CVE-2020-24512—INTEL-SA-00464
- CVE-2021-0127—INTEL-SA-00532
- CVE-2021-0146—INTEL-SA-00528
- CVE-2021-0086—INTEL-SA-00516
- CVE-2021-0089—INTEL-SA-00516
- CVE-2021-33150—INTEL-SA-00609
- CVE-2022-0002—INTEL-SA-00598
For additional information, refer to Mitsubishi Electric’s bulletin.
Mitsubishi Electric recommends that users take the following mitigation measures to minimize the risk of exploiting these vulnerabilities:
- Restrict physical access to the product from unauthorized users.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:
- Do not click web links or open attachments in unsolicited email messages.
- Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
- Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.
No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely. These vulnerabilities have a high attack complexity.
This product is provided subject to this Notification and this Privacy & Use policy.