SystemK NVR 504/508/516
1. EXECUTIVE SUMMARY
- CVSS v3 9.8
- ATTENTION: Exploitable remotely/low attack complexity/public exploits are available
- Vendor: SystemK
- Equipment: NVR 504/508/516
- Vulnerability: Command Injection
2. RISK EVALUATION
Successful exploitation of this vulnerability could allow an attacker to execute commands with root privileges.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following versions of SystemK NVR, a network video recorder, are affected:
- NVR 504: 2.3.5SK.30084998
- NVR 508: 2.3.5SK.30084998
- NVR 516: 2.3.5SK.30084998
3.2 Vulnerability Overview
3.2.1 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND ('COMMAND INJECTION') CWE-77
SystemK NVR 504/508/516 versions 2.3.5SK.30084998 and prior are vulnerable to a command injection vulnerability in the dynamic domain name system (DDNS) settings that could allow an attacker to execute arbitrary commands with root privileges.
CVE-2023-7227 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
3.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities
- COUNTRIES/AREAS DEPLOYED: Worldwide
- COMPANY HEADQUARTERS LOCATION: Japan
3.4 RESEARCHER
CISA discovered a public Proof of Concept (PoC) as authored by Keniver Wang.
4. MITIGATIONS
SystemK has not responded to requests to work with CISA to mitigate this vulnerability. Users of affected versions of SystemK NVR products are invited to contact SystemK customer support for additional information.
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:
- Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
- Locate control system networks and remote devices behind firewalls and isolating them from business networks.
- When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.