ICS Advisory

Siemens RUGGEDCOM APE1808 Devices

Release Date
Alert Code
ICSA-25-135-01

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 6.3
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: RUGGEDCOM APE1808 Devices
  • Vulnerabilities: Insufficiently Protected Credentials, Out-of-bounds Write

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to retrieve LDAP credentials via modifying the LDAP server IP address in the FortiOS configuration to point to a malicious attacker-controlled server or cause a denial-of-service condition.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

Siemens reports that the following products are affected:

  • RUGGEDCOM APE1808: All versions

3.2 VULNERABILITY OVERVIEW

3.2.1 INSUFFICIENTLY PROTECTED CREDENTIALS CWE-522

An insufficiently protected credentials vulnerability in FortiOS may allow a privileged authenticated attacker to retrieve LDAP credentials via modifying the LDAP server IP address in the FortiOS configuration to point to a malicious attacker-controlled server.

CVE-2024-32122 has been assigned to this vulnerability. A CVSS v3.1 base score of 2.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N).

A CVSS v4 score has also been calculated for CVE-2024-32122. A base score of 2.0 has been calculated; the CVSS vector string is (CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N).

3.2.2 OUT-OF-BOUNDS WRITE CWE-787

A out-of-bounds write in Fortinet FortiOS versions 7.6.0, 7.4.0 through 7.4.6, 7.2.0 through 7.2.10, 7.0.0 through 7.0.16, 6.4.0 through 6.4.15 allows attacker to trigger a denial-of-service via specially crafted packets.

CVE-2024-52963 has been assigned to this vulnerability. A CVSS v3.1 base score of 3.7 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L).

A CVSS v4 score has also been calculated for CVE-2024-52963. A base score of 6.3 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • Contact customer support to receive patch and update information.
  • (CVE-2024-52963) Under the config vpn ipsec phase1-interface configuration, either set authmethod to psk, or set digital-signature-auth to disable (see https://fortiguard.fortinet.com/psirt/FG-IR-24-373)

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-864900 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • May 15, 2025: Initial Republication of Siemens SSA-864900

This product is provided subject to this Notification and this Privacy & Use policy.

Vendor

  • Siemens