ICS Advisory

Siemens INTRALOG WMS

Release Date
Alert Code
ICSA-25-135-02

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 8.7
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: INTRALOG WMS
  • Vulnerabilities: Cleartext Transmission of Sensitive Information, Uncontrolled Resource Consumption, Use After Free, Improper Link Resolution Before File Access ('Link Following'), Improper Input Validation, Inefficient Algorithmic Complexity

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to bypass security features, cause a denial-of-service condition, or execute arbitrary code.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

Siemens reports that the following products are affected:

  • Siemens INTRALOG WMS: All versions prior to v5

3.2 VULNERABILITY OVERVIEW

3.2.1 CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319

Microsoft.Data.SqlClient and System.Data.SqlClient SQL Data Provider Security Feature Bypass Vulnerability

CVE-2024-0056 has been assigned to this vulnerability. A CVSS v3 base score of 8.7 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:N).

3.2.2 UNCONTROLLED RESOURCE CONSUMPTION CWE-400

.NET Denial-of-Service Vulnerability

CVE-2024-20672 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.3 UNCONTROLLED RESOURCE CONSUMPTION CWE-400

.NET and Visual Studio Denial-of-Service Vulnerability

CVE-2024-30105 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.4 USE AFTER FREE CWE-416

.NET and Visual Studio Remote Code Execution Vulnerability

CVE-2024-35264 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).

.NET, .NET Framework, and Visual Studio Elevation of Privilege Vulnerability

CVE-2024-38081 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H).

3.2.6 IMPROPER INPUT VALIDATION CWE-20

.NET and Visual Studio Denial-of-Service Vulnerability

CVE-2024-38095 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.7 INEFFICIENT ALGORITHMIC COMPLEXITY CWE-407

.NET, .NET Framework, and Visual Studio Denial of Service Vulnerability

CVE-2024-43483 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.8 INEFFICIENT ALGORITHMIC COMPLEXITY CWE-407

.NET and Visual Studio Denial-of-Service Vulnerability

CVE-2024-43485 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Chemical, Energy, Food and Agriculture, Healthcare and Public Health, Transportation Systems, and Water and Wastewater Systems
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has released version V5 of INTRALOG WMS and recommends updating to this version or later. Please contact your INTRALOG WMS representative to address the reported vulnerabilities in your solution. When reaching out to your Siemens representative, kindly reference the Siemens Security Advisory ID (SSA-901508).

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-901508 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • May 15, 2025: Initial Republication of Siemens SSA-901508

This product is provided subject to this Notification and this Privacy & Use policy.

Vendor

  • Siemens