End-of-Train and Head-of-Train Remote Linking Protocol (Update C)
1. EXECUTIVE SUMMARY
- CVSS v4 7.2
- ATTENTION: Low attack complexity
- Standard: End-of-Train and Head-of-Train remote linking protocol
- Equipment: End-of-Train and Head-of-Train devices
- Vulnerability: Weak Authentication
2. RISK EVALUATION
Successful exploitation of this vulnerability could allow an attacker to send their own brake control commands to the end-of-train device, causing a sudden stoppage of the train which may lead to a disruption of operations, or induce brake failure.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following version of End-of-Train and Head-of-Train remote linking protocol is affected:
- End-of-Train and Head-of-Train remote linking protocol: All versions
The following specific devices have been confirmed to be affected by their respective manufacturers:
- Wabtec TrainLink NG End of Train (NGEOT)
- Wabtec TrainLink NG3 ATX End of Train (NG3 EOT)
- Wabtec TrainLink NG4 ATX End of Train (NG4 EOT)
- Wabtec TrainLink NG5 ATX End of Train (NG5 EOT)
- Siemens Trainguard EOT
- Siemens Trainguard HOT
- DPS Electronics DPS 2020-He-LD: ETD External 2dB Antenna
- DPS Electronics DPS 2020-He: ETD Internal Antenna
- DPS Electronics DPS 3030-CM-MAG: HTD Console Mount
- DPS Electronics DPS 3030-I-MAG HTD: HTD Integrated
3.2 VULNERABILITY OVERVIEW
3.2.1 WEAK AUTHENTICATION CWE-1390
The protocol used for remote linking over RF for End-of-Train and Head-of-Train (also known as a FRED) relies on a BCH checksum for packet creation. It is possible to create these EoT and HoT packets with a software defined radio and issue brake control commands to the EoT device, disrupting operations or potentially overwhelming the brake systems.
CVE-2025-1727 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2025-1727. A base score of 7.2 has been calculated; the CVSS vector string is (AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:H/SA:H).
3.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Transportation Systems
- COUNTRIES/AREAS DEPLOYED: United States
- COMPANY HEADQUARTERS LOCATION: United States
3.4 RESEARCHER
Neil Smith and Eric Reuter reported this vulnerability to CISA.
4. MITIGATIONS
The Association of American Railroads (AAR) is pursuing new equipment and protocols which should replace traditional End-of-Train and Head-of-Train devices. The standards committees involved in these updates are aware of the vulnerability and are investigating mitigating solutions.
The AAR Railroad Electronics Standards Committee (RESC) maintains this protocol which is used by multiple manufacturers across the industry.
Known affected vendors are:
- Wabtec
- Siemens
- DPS Electronics
Users of EoT/HoT devices are recommended to contact their own device manufacturers with questions.
Wabtec directs users to visit their cybersecurity page for additional information.
Siemens advises users of Trainguard devices to reference the associated security bulletin.
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:
- Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
- Locate control system networks and remote devices behind firewalls and isolating them from business networks.
- When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.
5. UPDATE HISTORY
- July 10, 2025: Initial Publication
- August 12, 2025: Update A- Removed Hitachi from list of affected vendors, adjusted formatting
- September 4, 2025: Update B- Added affected device list and cybersecurity page for Wabtec products, added DPS Electronics as an affected vendor
- September 18, 2025: Update C- Expanded affected device list with Siemens and DPS Electronics products
This product is provided subject to this Notification and this Privacy & Use policy.