ICS Advisory

Hitachi Energy Asset Suite

Release Date
Alert Code
ICSA-25-261-04

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 8.7
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Hitachi Energy
  • Equipment: Asset Suite
  • Vulnerabilities: Server-Side Request Forgery (SSRF), Deserialization of Untrusted Data, Cleartext Storage of Sensitive Information, Uncontrolled Resource Consumption, URL Redirection to Untrusted Site ('Open Redirect'), Improper Authentication

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow attackers to trigger resource consumption or information disclosure through SSRF in Apache XML Graphics Batik, mount a Denial-Of-Service attack via poisoned data in logback, discover cleartext passwords in H2 Database Engine, fill up the file system in Apache CXF, perform open redirect or SSRF attacks through UriComponentsBuilder, and execute arbitrary code in Apache ActiveMQ.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

Hitachi Energy reports that the following products are affected:

  • Asset Suite: Versions 9.6.4.5 and prior

3.2 VULNERABILITY OVERVIEW

3.2.1 SERVER-SIDE REQUEST FORGERY (SSRF) CWE-918

Server-Side Request Forgery (SSRF) vulnerability in Apache Software Foundation Apache XML Graphics Batik. This issue affects Apache XML Graphics Batik: 1.16. On version 1.16, a malicious SVG could trigger loading external resources by default, causing resource consumption or in some cases even information disclosure.

CVE-2022-44729 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.1 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H).

A CVSS v4 score has also been calculated for CVE-2022-44729. A base score of 6.9 has been calculated; the CVSS vector string is (CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:N/VA:H/SC:N/SI:N/SA:N).

3.2.2 DESERIALIZATION OF UNTRUSTED DATA CWE-502

A serialization vulnerability in logback receiver component part of logback version 1.4.11 allows an attacker to mount a Denial-of-Service attack by sending poisoned data. This vulnerability affects logback versions prior to 1.2.13, 1.3.12 and 1.4.12.

CVE-2023-6378 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

A CVSS v4 score has also been calculated for CVE-2023-6378. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N).

3.2.3 CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312

The web-based admin console in H2 Database Engine before 2.2.220 can be started via the CLI with the argument -webAdminPassword, which allows the user to specify the password in cleartext for the web admin console. Consequently, a local user (or an attacker that has obtained local access through some means) would be able to discover the password by listing processes and their arguments. The issue was fixed in 2.2.220 by the vendor H2.

CVE-2022-45868 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2022-45868. A base score of 8.5 has been calculated; the CVSS vector string is (CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.4 UNCONTROLLED RESOURCE CONSUMPTION CWE-400

A potential denial of service vulnerability is present in versions of Apache CXF before 3.5.10, 3.6.5 and 4.0.6. In some edge cases, the CachedOutputStream instances may not be closed and, if backed by temporary files, may fill up the file system (it applies to servers and clients).

CVE-2025-23184 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

A CVSS v4 score has also been calculated for CVE-2025-23184. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N).

3.2.5 URL REDIRECTION TO UNTRUSTED SITE ('OPEN REDIRECT') CWE-601

Applications that use UriComponentsBuilder to parse an externally provided URL (e.g. through a query parameter) AND perform validation checks on the host of the parsed URL may be vulnerable to a open redirect attack or to a SSRF attack if the URL is used after passing validation checks.

CVE-2024-22262 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.1 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N).

A CVSS v4 score has also been calculated for CVE-2024-22262. A base score of 8.6 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N).

3.2.6 IMPROPER AUTHENTICATION CWE-287

In Apache ActiveMQ, once a user is authenticated on Jolokia, the user can potentially trigger arbitrary code execution. In details, in ActiveMQ configurations, jetty allows org.jolokia.http.AgentServlet to handle request to /api/jolokia org.jolokia.http.HttpRequestHandler#handlePostRequest is able to create JmxRequest through JSONObject. And calls to org.jolokia.http.HttpRequestHandler#executeRequest. Into deeper calling stacks, org.jolokia.handler.ExecHandler#doHandleRequest can be invoked through reflection. This could lead to RCE through via various mbeans.

CVE-2022-41678 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2022-41678. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Energy
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Switzerland

3.4 RESEARCHER

Hitachi Energy PSIRT reported these vulnerabilities to CISA.

4. MITIGATIONS

Hitachi Energy has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • Asset Suite versions 9.6.4.5 and prior: Apply general mitigation factors
  • (CVE-2022-44729, CVE-2023-6378, CVE-2022-45868, CVE-2025-23184, CVE-2024-22262) Asset Suite versions 9.6.4.5 and prior: Upgrade to version 9.7
  • (CVE-2022-41678) Asset Suite versions 9.6.4.5 and prior: Upgrade to version 9.8 when available

For more information see the associated Hitachi Energy PSIRT security advisory 8DBD000221 Multiple Open-Source Software Vulnerabilities in Hitachi Energy Asset Suite Product.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • September 18, 2025: Initial Republication of Hitachi Energy PSIRT 8DBD000221

This product is provided subject to this Notification and this Privacy & Use policy.

Vendor