Archived Content
In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.Philips Tasy EMR
1. EXECUTIVE SUMMARY
- CVSS v3 8.8
- ATTENTION: Exploitable remotely/low attack complexity/public exploits are available
- Vendor: Philips
- Equipment: Tasy EMR
- Vulnerabilities: SQL Injection
2. RISK EVALUATION
Successful exploitation of these vulnerabilities could result in patient’s confidential data being exposed or extracted from Tasy’s database, give unauthorized access, or create a denial-of-service condition.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
Philips reports these vulnerabilities affect the following Philips Healthcare Tasy Electronic Medical Record (EMR) products:
- Tasy EMR HTML5 3.06.1803 and prior
3.2 VULNERABILITY OVERVIEW
3.2.1 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN SQL COMMAND ('SQL INJECTION') CWE-89
The affected product allows SQL injection via the WAdvancedFilter/getDimensionItemsByCode FilterValue parameter.
CVE-2021-39375 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
3.2.2 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN SQL COMMAND ('SQL INJECTION') CWE-89
The affected product allows SQL injection via the CorCad_F2/executaConsultaEspecifico IE_CORPO_ASSIST or CD_USUARIO_CONVENIO parameter.
CVE-2021-39376 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
3.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Healthcare and Public Health
- COUNTRIES/AREAS DEPLOYED: Argentina, Brazil, Colombia, Dominican Republic, Mexico
- COMPANY HEADQUARTERS LOCATION: Netherlands
3.4 RESEARCHER
These vulnerabilities were disclosed without coordination by a security researcher. Philips reported the publicly disclosed vulnerability to CISA.
4. MITIGATIONS
Philips recommends users update Tasy EMR HTML5 to Version 3.06.1804 or later with the latest available service pack where both CVEs are remediated.
Users with questions regarding their specific Philips TASY EMR system are advised by Philips to contact their Customer Success Manager (CSM), local Philips service support team, or regional service support. Users can also contact Philips on its company website.
The Philips advisory for these vulnerabilities is available on Philips product security website.
Please see the Philips product security website for the latest security information for Philips products.
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:
- Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.
- Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
- When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
This product is provided subject to this Notification and this Privacy & Use policy.
Vendor
- Philips