Siemens Siveillance Video
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).
1. EXECUTIVE SUMMARY
- CVSS v4 5.5
- ATTENTION: Exploitable remotely
- Vendor: Siemens
- Equipment: Siveillance Video
- Vulnerability: Missing Encryption of Sensitive Data
2. RISK EVALUATION
Successful exploitation of this vulnerability could remove password protection from the system configuration files, also affecting backup data sets that were created after the update to V2024 R1.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
Siemens reports that the following products are affected:
- Siemens Siveillance Video: Versions V24.1 and later
3.2 VULNERABILITY OVERVIEW
3.2.1 MISSING ENCRYPTION OF SENSITIVE DATA CWE-311
Milestone Systems has discovered a security vulnerability in Milestone XProtect installer that resets system configuration password after the upgrading from older versions using specific installers. The system configuration password is an additional, optional protection that is enabled on the Management Server. To mitigate the issue, we highly recommend updating system configuration password via GUI with a standard procedure. Any system upgraded with 2024 R1 or 2024 R2 release installer is vulnerable to this issue. Systems upgraded from 2023 R3 or older with version 2025 R1 and newer are not affected.
CVE-2025-1688 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:L/I:L/A:L).
A CVSS v4 score has also been calculated for CVE-2025-1688. A base score of 5.5 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:H/AT:P/PR:H/UI:N/VC:L/VI:L/VA:L/SC:H/SI:H/SA:H).
3.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
- COUNTRIES/AREAS DEPLOYED: Worldwide
- COMPANY HEADQUARTERS LOCATION: Germany
3.4 RESEARCHER
Milestone PSIRT reported this vulnerability to Siemens.
4. MITIGATIONS
Siemens has identified the following specific workarounds and mitigations that users can apply to reduce risk:
- Siveillance Video: Change the system configuration password settings (see page 268 in "Siveillance Video 2024 R1 Administrator Manual")
- Siveillance Video: Currently no fix is available
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage
For more information, see the associated Siemens security advisory SSA-552330 in HTML and CSAF.
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:
- Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
- Locate control system networks and remote devices behind firewalls and isolating them from business networks.
- When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:
- Do not click web links or open attachments in unsolicited email messages.
- Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
- Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.
No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity.
5. UPDATE HISTORY
- May 20, 2025: Initial Republication of Siemens SSA-552330
This product is provided subject to this Notification and this Privacy & Use policy.
Vendor
- Siemens