Parsons AccuWeather Widget
1. EXECUTIVE SUMMARY
- CVSS v4 8.7
- ATTENTION: Exploitable remotely/low attack complexity
- Vendor: Parsons
- Equipment: AccuWeather and Custom RSS widget
- Vulnerability: Cross-site Scripting
2. RISK EVALUATION
Successful exploitation of this vulnerability could allow an attacker to insert a malicious link that users might access through the RSS feed.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following version of AccuWeather and Custom RSS widget are affected:
- Parsons Utility Enterprise Data Management: Version 5.18
- Parsons Utility Enterprise Data Management: Version 5.03
- Parsons Utility Enterprise Data Management: Versions 4.02 through 4.26
- Parsons Utility Enterprise Data Management: Version 3.30
- AclaraONE Utility Portal: versions prior to 1.22
3.2 VULNERABILITY OVERVIEW
3.2.1 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-79
A cross-site scripting vulnerability exists in the AccuWeather and Custom RSS widget that allows an unauthenticated user to replace the RSS feed URL with a malicious one.
CVE-2025-5015 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2025-5015. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Communications
- COUNTRIES/AREAS DEPLOYED: Worldwide
- COMPANY HEADQUARTERS LOCATION: United States
3.4 RESEARCHER
Joshua Dillon reported this vulnerability to CISA.
4. MITIGATIONS
- Parsons Utility Enterprise Data Management Users - This vulnerability has been patched in all instances managed by Parsons as of January 7, 2025. No end-user action is required.
- AclaraONE Hosted Users – This vulnerability has been patched in all instances managed by Aclara as of February 7, 2025. No end-user action is required.
- AclaraONE On Premise Users - End-user action is required. A patch and mitigation information for AclaraONE is available through the Aclara Connect Customer Portal. If you prefer assistance, Aclara Support would be happy to help. Users may request an appointment to apply the patch update by opening a ticket on the Aclara Connect Customer Portal, or by contacting us by phone or email. Requests will be processed in the order received.
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:
- Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
- Locate control system networks and remote devices behind firewalls and isolating them from business networks.
- When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.
5. UPDATE HISTORY
- June 24, 2025: Initial Publication