ICS Advisory

Advantech iView

Release Date
Alert Code
ICSA-25-191-08

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 8.7
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Advantech
  • Equipment: iView
  • Vulnerabilities: Cross-site Scripting, SQL Injection, Path Traversal, Argument Injection.

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to disclose sensitive information, achieve remote code execution, or cause service disruptions.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following Advantech products are affected:

  • iView: Versions prior to 5.7.05 build 7057

3.2 VULNERABILITY OVERVIEW

3.2.1 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-79

A vulnerability exists in Advantech iView versions prior to 5.7.05 build 7057, which could allow a reflected cross-site scripting (XSS) attack. By exploiting this flaw, an attacker could execute unauthorized scripts in the user's browser, potentially leading to information disclosure or other malicious activities.

CVE-2025-53397 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N).

A CVSS v4 score has also been calculated for CVE-2025-53397. A base score of 5.1 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N).

3.2.2 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-79

A vulnerability exists in Advantech iView versions prior to 5.7.05 build 7057, which could allow a reflected cross-site scripting (XSS) attack. By manipulating specific parameters, an attacker could execute unauthorized scripts in the user's browser, potentially leading to information disclosure or other malicious activities.

CVE-2025-53519 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N).

A CVSS v4 score has also been calculated for CVE-2025-53519. A base score of 5.1 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N).

3.2.3 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-79

A vulnerability exists in Advantech iView versions prior to 5.7.05 build 7057, which could allow a reflected cross-site scripting (XSS) attack. By manipulating certain input parameters, an attacker could execute unauthorized scripts in the user's browser, potentially leading to information disclosure or other malicious activities.

CVE-2025-41442 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N).

A CVSS v4 score has also been calculated for CVE-2025-41442. A base score of 5.1 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N).

3.2.4 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-89

A vulnerability exists in Advantech iView that could allow for SQL injection through the CUtils.checkSQLInjection() function. This vulnerability can be exploited by an authenticated attacker with at least user-level privileges, potentially leading to information disclosure or a denial-of-service condition.

CVE-2025-48891 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L).

A CVSS v4 score has also been calculated for CVE-2025-48891. A base score of 7.2 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N).

3.2.5 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') CWE-22

A vulnerability exists in Advantech iView in NetworkServlet.processImportRequest() that could allow for a directory traversal attack. This issue requires an authenticated attacker with at least user-level privileges. A specific parameter is not properly sanitized or normalized, potentially allowing an attacker to determine the existence of arbitrary files on the server.

CVE-2025-46704 has been assigned to this vulnerability. A CVSS v3.1 base score of 4.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N).

A CVSS v4 score has also been calculated for CVE-2025-46704. A base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N).

3.2.6 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-89

A vulnerability exists in Advantech iView that could allow for SQL injection and remote code execution through NetworkServlet.getNextTrapPage(). This issue requires an authenticated attacker with at least user-level privileges. Certain parameters in this function are not properly sanitized, allowing an attacker to perform SQL injection and potentially execute code in the context of the 'nt authority\local service' account.

CVE-2025-53475 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-53475. A base score of 8.7 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.7 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-89

A vulnerability exists in Advantech iView that could allow SQL injection and remote code execution through NetworkServlet.archiveTrapRange(). This issue requires an authenticated attacker with at least user-level privileges. Certain input parameters are not properly sanitized, allowing an attacker to perform SQL injection and potentially execute code in the context of the 'nt authority\local service' account.

CVE-2025-52577 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-52577. A base score of 8.7 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.8 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-89

A vulnerability exists in Advantech iView that allows for SQL injection and remote code execution through NetworkServlet.archiveTrap(). This issue requires an authenticated attacker with at least user-level privileges. Certain input parameters are not sanitized, allowing an attacker to perform SQL injection and potentially execute code in the context of the 'nt authority\local service' account.

CVE-2025-53515 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-53515. A base score of 8.7 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.9 Improper Neutralization of Argument Delimiters in a Command ('Argument Injection') CWE-88

A vulnerability exists in Advantech iView that allows for argument injection in NetworkServlet.backupDatabase(). This issue requires an authenticated attacker with at least user-level privileges. Certain parameters can be used directly in a command without proper sanitization, allowing arbitrary arguments to be injected. This can result in information disclosure, including sensitive database credentials.

CVE-2025-52459 has been assigned to this vulnerability. A CVSS v3.1 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).

A CVSS v4 score has also been calculated for CVE-2025-52459. A base score of 7.1 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).

3.2.10 Improper Neutralization of Argument Delimiters in a Command ('Argument Injection') CWE-88

A vulnerability exists in Advantech iView that allows for argument injection in the NetworkServlet.restoreDatabase(). This issue requires an authenticated attacker with at least user-level privileges. An input parameter can be used directly in a command without proper sanitization, allowing arbitrary arguments to be injected. This can result in information disclosure, including sensitive database credentials.

CVE-2025-53509 has been assigned to this vulnerability. A CVSS v3.1 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).

A CVSS v4 score has also been calculated for CVE-2025-53509. A base score of 7.1 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Taiwan

3.4 RESEARCHER

Alex Williams of Converge Technology Solutions reported these vulnerabilities to CISA.

4. MITIGATIONS

Advantech recommends users update to v5.7.05 build 7057.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • July 10, 2025: Initial Publication