ICS Advisory

LG Innotek Camera Multiple Models

Release Date
Alert Code
ICSA-25-273-07

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 8.8
  • ATTENTION: Exploitable remotely/Low attack complexity
  • Vendor: LG Innotek
  • Equipment: Camera Models LND7210 and LNV7210R
  • Vulnerability: Authentication Bypass Using an Alternate Path or Channel

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to gain administrative access to the device.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following models of LG Innotek CCTV Cameras are affected:

  • LG LND7210: All Versions
  • LG LNV7210R: All Versions

3.2 VULNERABILITY OVERVIEW

3.2.1 Authentication Bypass Using an Alternate Path or Channel CWE-288

An authentication bypass vulnerability exists in LG Innotek camera models LND7210 and LNV7210R. The vulnerability allows a malicious actor to gain access to camera information including user account information.

CVE-2025-10538 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L).

A CVSS v4 score has also been calculated for CVE-2025-10538. A base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: South Korea

3.4 RESEARCHER

Souvik Kandar reported this vulnerability to CISA.

4. MITIGATIONS

LG Innotek is aware of the vulnerability but has noted this is an end-of-life product that can no longer be patched.

Visit the LG Security Center for further guidance.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

  • September 30, 2025: Initial Publication