ICS Advisory

LITEON IC48A and IC80A EV Chargers

Release Date
Alert Code
ICSA-25-196-03

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 8.7
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: LITEON
  • Equipment: IC48A and IC80A
  • Vulnerability: Plaintext Storage of a Password

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to access sensitive information when accessing the Liteon EV chargers.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of LITEON EV chargers are affected:

  • LITEON IC48A: Firmware versions prior to 01.00.19r
  • LITEON IC80A: Firmware versions prior to 01.01.12e

3.2 VULNERABILITY OVERVIEW

3.2.1 PLAINTEXT STORAGE OF A PASSWORD CWE-256

LITEON IC48A firmware versions prior to 01.00.19r and LITEON IC80A firmware versions prior to 01.01.12e store FTP-server-access-credentials in cleartext in their system logs.

CVE-2025-7357 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

A CVSS v4 score has also been calculated for CVE-2025-7357. A base score of 8.7 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities, Energy, Transportation Systems
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Taiwan

3.4 RESEARCHER

Murat Sagdullaev of Electrada reported this vulnerability to CISA.

4. MITIGATIONS

LITEON has released the following firmware versions for the following EV chargers:

  • LITEON IC48A: Firmware versions 01.00.20h
  • LITEON IC80A: Firmware versions 01.01.13m

For more information, contact LITEON.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

  • July 15, 2025: Initial Publication

This product is provided subject to this Notification and this Privacy & Use policy.