LG Innotek Camera Model LNV5110R
1. EXECUTIVE SUMMARY
- CVSS v4 8.3
- ATTENTION: Exploitable remotely
- Vendor: LG Innotek
- Equipment: Camera Model LNV5110R
- Vulnerability: Authentication Bypass Using an Alternate Path or Channel
2. RISK EVALUATION
Successful exploitation of this vulnerability could allow an attacker to gain administrative access to the device.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following model of LG Innotek CCTV Camera is affected:
- LNV5110R: All versions
3.2 Vulnerability Overview
3.2.1 AUTHENTICATION BYPASS USING AN ALTERNATE PATH OR CHANNEL CWE-288
An authentication vulnerability exists in the LG Innotek camera model LNV5110R firmware that allows a malicious actor to upload an HTTP POST request to the devices non-volatile storage. This action may result in remote code execution that allows an attacker to run arbitrary commands on the target device at the administrator privilege level.
CVE-2025-7742 has been assigned to this vulnerability. A CVSS v3 base score of 7.0 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:L).
A CVSS v4 score has also been calculated for CVE-2025-7742. A base score of 8.3 has been calculated; the CVSS vector string is (AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N).
3.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities
- COUNTRIES/AREAS DEPLOYED: Worldwide
- COMPANY HEADQUARTERS LOCATION: South Korea
3.4 RESEARCHER
Souvik Kandar reported this vulnerability to CISA.
4. MITIGATIONS
LG Innotek is aware of the vulnerability but has noted this is an end-of-life product that can no longer be patched.
Please visit the LG Security Center for further guidance.
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:
- Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.
- Locate control system networks and remote devices behind firewalls and isolating them from business networks.
- When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity.
5. UPDATE HISTORY
- July 24, 2025: Initial Publication
This product is provided subject to this Notification and this Privacy & Use policy.